Microscopy - 12th Micro Biology MCQ with Answers
Chapter 2 of 12th Micro Biology explains three advanced microscopes: the phase contrast microscope with its annular diaphragm and phase plate, the fluorescence microscope with fluorophores, filters and a mercury arc lamp, and the electron microscope, covering TEM, SEM, STEM, specimen preparation and how they differ from light microscopes.
Study this chapter
Asked in previous board exams
4 questions from this chapter came in 3 past public exams. Open any of them to see the answer and explanation.
-
March 2026
________ is an example for optical imaging technique.See answer in the solved paper →
-
March 2026
Lens used in TEM is ________.See answer in the solved paper →
-
March 2025
Which among the following helps us in getting a 3-D picture of specimen ?See answer in the solved paper →
-
March 2023
Match the following : (1) SEM - (i) 2 dimensional image (2) TEM - (ii) Unstained living cell (3) Fluorescence microscope - (iii) 3 dimensional image (4) PCM - (iv) Mycobacterium tuberculosisSee answer in the solved paper →
About Microscopy
Medium ~50 min study
Microscopy is the second chapter of the Tamil Nadu State Board Class 12 Micro Biology book. Having studied bright field and dark field microscopes in Class 11, students now learn the phase contrast and fluorescence microscopes, and the electron microscope, which uses an electron beam instead of light.
The chapter names the scientists behind each instrument, from Stokes in 1852 to Zernike, Ruska and Knoll, and ends with tables comparing light and electron microscopes, and SEM and TEM. These MCQs cover all ten book-back questions and further questions drawn from every section.
What you'll learn
- Identify the components of phase contrast, fluorescence and electron microscopes.
- Explain how the phase contrast microscope converts phase changes into contrast.
- Describe fluorescence, Stokes shift and the role of each filter in a fluorescence microscope.
- Outline specimen preparation for TEM and SEM.
- Differentiate light and electron microscopes, and SEM and TEM.
- List the applications of phase contrast, fluorescence and electron microscopes.
Before you start
- Bright field and dark field microscopes studied in Class 11 Micro Biology.
- Basic ideas of wavelength, refraction and refractive index of light.
- Parts of a compound microscope: light source, condenser, objective and ocular.
Topics covered in this chapter
Microscopy explained
What this chapter covers
Phase contrast microscope
Frits Zernike's microscope turns tiny phase changes, about one-fourth of a wavelength, into differences in brightness. The sub-stage annular diaphragm and the phase plate coated with magnesium fluoride make this possible, so unstained living cells can be seen.
Fluorescence microscope
A fluorophore absorbs short wavelength light and emits a longer wavelength (Stokes shift). A mercury arc or xenon lamp, excitation, emission and dichroic filters, and dyes such as DAPI, FITC and Texas Red are used.
Electron microscope
Ruska and Knoll invented it in 1931. Electromagnetic lenses, vacuum and heavy metal stains give far higher resolution. TEM shows interiors in two dimensions; SEM shows surfaces in three dimensions.
Common mistakes to avoid
- Saying phase contrast needs stained cells. Its main use is viewing unstained living cells.
- Thinking fluorescence is emitted at a shorter wavelength. Emission is always at a longer wavelength (Stokes shift).
- Placing the TEM sample at the bottom of the column. It sits in the middle; in SEM it is at the bottom.
- Mixing up SEM and TEM images. SEM gives 3-D surface images; TEM gives 2-D images of the interior.
- Assuming electron microscope lenses are glass. All its lenses are electromagnetic.
Test yourself on these with the practice test, then check the worked reasoning in the solved MCQs.
Frequently asked questions
Who invented the phase contrast microscope?
Frits Zernike, a Dutch physicist, invented it and received the Nobel Prize in 1953. It allows the observation of living cells.
How does a phase contrast microscope differ from a bright field microscope?
It has a sub-stage annular diaphragm and a phase plate, which convert minute phase changes in light into brightness changes that the eye can detect.
What is Stokes shift?
Fluorescence emission always occurs at a longer wavelength than the excitation light. This shift towards longer wavelength, noted by George Stokes, is the Stokes shift.
Why is fluorescence called cold light?
Because it does not come from a hot source like an incandescent light bulb.
Which light source is used in a fluorescence microscope?
A powerful xenon or mercury arc lamp. The mercury arc lamp is 10-100 times brighter than most incandescent lamps; lasers or high-power LEDs are used for complex techniques.
Why is vacuum essential in an electron microscope?
Emitted electrons travel through the microscope column, and vacuum prevents strong scattering of the electrons by gases.
Who invented the electron microscope?
Two German scientists, Ernst Ruska and Max Knoll, in 1931. Ruska received the Nobel Prize in 1986, and Knoll first built the SEM in 1935.
Last updated 28 October 2026