24 extra multiple-choice questions for Microscopy (12th Standard Micro Biology, Samacheer Kalvi), beyond the ones printed in the textbook — each with the correct option highlighted and a clear, worked explanation. Free to read in English and Tamil.
Q1
Frits Zernike was awarded the Nobel Prize for inventing the phase contrast microscope in the year
- A. 1931
- B. 1953Correct
- C. 1986
- D. 1924
Explanation. Frits Zernike, a Dutch physicist, invented the phase contrast microscope and received the Nobel Prize in 1953. Ernst Ruska received his Nobel Prize in 1986 for the electron microscope.
Q2
The light retarding material coated on one portion of the phase plate is
- A. Magnesium fluorideCorrect
- B. Osmium tetroxide
- C. Uranyl acetate
- D. Lead acetate
Explanation. The phase plate, at the back focal plane of the objective, has one portion coated with the light retarding material magnesium fluoride; the other portion lacks it but can absorb light.
Q3
In a phase contrast microscope, the phase difference between the retarded (deviated) and un-retarded (non-deviated) light rays is about
- A. One-half of the original wavelength
- B. One-fourth of the original wavelengthCorrect
- C. Twice the original wavelength
- D. One-tenth of the original wavelength
Explanation. The difference in phase between retarded and un-retarded rays is about one-fourth of the original wavelength (\( \lambda/4 \)). Human eyes cannot detect such minute changes, so the annular diaphragm and phase plate convert them into brightness changes.
Q4
In a phase contrast microscope, the separation of the diffracted waves from the direct waves is achieved by the
- A. Phase plate
- B. Ocular lens
- C. Sub-stage annular diaphragmCorrect
- D. Objective lens
Explanation. To get contrast the diffracted waves must be separated from the direct waves. This separation is achieved by the sub-stage annular diaphragm, which illuminates the specimen with a hollow cone of light.
Q5
Which of the following are applications of the phase contrast microscope?
1. Visualisation of unstained living cells
2. Study of cell division
3. Visualisation of chromosomal and flagellar movements
4. Study of porosity in ceramics
- A. 1 and 2 only
- B. 1, 2 and 3 onlyCorrect
- C. 2, 3 and 4 only
- D. 1 and 4 only
Explanation. PCM visualises unstained living cells, helps study cell division and shows chromosomal and flagellar movements. Studying porosity in ceramics with a fluorescent dye is an application of the fluorescence microscope.
Q6
Who first described fluorescence in 1852?
- A. Frits Zernike
- B. Sir George G. StokesCorrect
- C. Ernst Ruska
- D. Manu Prakash
Explanation. British scientist Sir George G. Stokes first described fluorescence in 1852. He observed that the fluorophore emitted red light when it was illuminated by ultraviolet excitation.
Q7
Stokes shift refers to the
- A. Shift of fluorescence emission towards a longer wavelength than the excitation lightCorrect
- B. Shift of fluorescence emission towards a shorter wavelength than the excitation light
- C. Phase change of light passing through a dense region of a cell
- D. Bending of the electron beam by electromagnetic lenses
Explanation. Stokes noted that fluorescence emission always occurs at a longer wavelength than the excitation light. This shift towards longer wavelength is known as Stokes shift.
Q8
Match the fluorophore with the colour it emits.
A. DAPI - 1. Red
B. FITC - 2. Blue
C. Texas Red - 3. Green
- A. A-2, B-3, C-1Correct
- B. A-3, B-2, C-1
- C. A-1, B-3, C-2
- D. A-2, B-1, C-3
Explanation. The three most common fluorophores are diamidino-phenylindole (DAPI), which emits blue, fluorescein isothiocyanate (FITC), which emits green, and Texas Red, which emits red.
Q9
The light emitted from the mercury arc lamp of a fluorescence microscope is brighter than most incandescent lamps by about
- A. 2-5 times
- B. 10-100 timesCorrect
- C. 500-1000 times
- D. 250 times
Explanation. Fluorescence microscopy needs a very powerful light source such as a xenon or mercury arc lamp. The mercury arc lamp is 10-100 times brighter than most incandescent lamps and covers ultraviolet to infrared.
Q10
In a fluorescence microscope, the dichroic filter or beam splitter is placed between the excitation filter and the emission filter at an angle of
- A. 30 degrees
- B. 45 degreesCorrect
- C. 60 degrees
- D. 90 degrees
Explanation. The dichroic beam splitter sits between the excitation and emission filters at a 45 degree angle. It reflects the excitation wavelength towards the specimen and transmits the emission wavelength towards the detector.
Q11
Assertion (A): Fluorescence is called "cold light".
Reason (R): Fluorescence does not come from a hot source like an incandescent light bulb.
- A. Both A and R are true and R is the correct explanation of ACorrect
- B. Both A and R are true but R is not the correct explanation of A
- C. A is true but R is false
- D. A is false but R is true
Explanation. The lesson states that fluorescence is called cold light because it does not come from a hot source like an incandescent bulb, so R correctly explains A.
Q12
In episcopic fluorescence microscopy, which is the most common form today,
- A. The excitation light comes from below through a dark field condenser
- B. The objective lens acts as both condenser and objectiveCorrect
- C. Transmitted light is used to excite the specimen
- D. No exciter filter is used
Explanation. In episcopic fluorescence the excitation light comes from above the specimen through the objective lens, which acts as both condenser and objective. Quartz objective lenses are needed for deep ultraviolet excitation.
Q13
Which of the following is NOT an application of the fluorescence microscope listed in the lesson?
- A. Observing texture and structure of coal
- B. Studying porosity in ceramics
- C. Identifying Mycobacterium tuberculosis
- D. Visualising flagellar movements of living cellsCorrect
Explanation. Fluorescence microscopy is used to observe coal texture, study porosity in ceramics with a fluorescent dye and identify Mycobacterium tuberculosis. Visualising chromosomal and flagellar movements is listed as an application of the phase contrast microscope.
Q14
In 1924, which French scientist showed that an accelerated electron beam behaved like waves with a wavelength much shorter than molecules and atoms?
- A. Max Knoll
- B. De BroglieCorrect
- C. Ernst Ruska
- D. K. Reichert
Explanation. In 1924 the French scientist Dr. De Broglie showed that an electron beam, when accelerated, behaved like waves and had a wavelength much shorter than the sizes of molecules and atoms.
Q15
The electron microscope was invented in 1931 by
- A. Frits Zernike and George Stokes
- B. Ernst Ruska and Max KnollCorrect
- C. K. Reichert and O. Heimstadt
- D. De Broglie and Manu Prakash
Explanation. Two German scientists, Ernst Ruska and Max Knoll, invented the electron microscope in 1931. Ruska later received the Nobel Prize in 1986, and the TEM was the first type developed.
Q16
Arrange the following events in chronological order.
1. Ernst Ruska receives the Nobel Prize
2. Reichert and Heimstadt demonstrate a fluorescence microscope
3. Stokes first describes fluorescence
4. Knoll first builds the SEM
- A. 3, 2, 4, 1Correct
- B. 2, 3, 4, 1
- C. 3, 4, 2, 1
- D. 3, 2, 1, 4
Explanation. Stokes described fluorescence in 1852, Reichert and Heimstadt demonstrated a fluorescence microscope in 1911, Knoll first built the SEM in 1935 and Ruska received the Nobel Prize in 1986.
Q17
Electrons used in an electron microscope are considered as radiation with a wavelength in the range of
- A. 400-700 nm
- B. 0.001-0.01 nmCorrect
- C. 50-100 nm
- D. 0.25-0.3 nm
Explanation. Electrons are considered as radiation with wavelength of 0.001-0.01 nm, compared to the 400-700 nm wavelength of visible light used in an optical microscope.
Q18
For electron microscopy, the material is preserved by fixation first with
- A. Glutaraldehyde and then osmium tetroxideCorrect
- B. Osmium tetroxide and then glutaraldehyde
- C. Liquid propane and then alcohol
- D. Epoxy resin and then lead acetate
Explanation. The material is preserved by fixation with glutaraldehyde and then with osmium tetroxide. The fixed material is dehydrated, embedded in epoxy resin and sectioned with an ultra-microtome.
Q19
In TEM, the ultrathin sample sections are about __________ thick and are placed on a __________ grid.
- A. 50-100 nm, copperCorrect
- B. 20 nm, aluminium
- C. 1 nm, gold
- D. 500-700 nm, platinum
Explanation. TEM sections are ultrathin, about 50-100 nm thick. They are placed on a copper grid and exposed to electron dense materials such as lead acetate, uranyl acetate and phosphotungstate.
Q20
Which of the following statements about the TEM are correct?
1. The electron gun has a tungsten filament that emits electrons at 50,000-100,000 volts.
2. Vacuum prevents strong scattering of electrons by gases.
3. The sample is located at the bottom of the column.
4. Unscattered electrons hit a fluorescent screen to form the image.
- A. 1, 2 and 4 onlyCorrect
- B. 1 and 3 only
- C. 2, 3 and 4 only
- D. 1, 2, 3 and 4
Explanation. Statements 1, 2 and 4 are given in the lesson. In a TEM the sample is located in the middle of the column; it is in the SEM that samples sit at the bottom of the electron column.
Q21
In preparing a specimen for SEM, it is first fixed in __________ and then dehydrated in alcohol at -70 °C.
- A. Glutaraldehyde at room temperature
- B. Liquid propane at -180 °CCorrect
- C. Osmium tetroxide at -70 °C
- D. Alcohol at -180 °C
Explanation. The SEM specimen is first fixed in liquid propane at -180 °C and dehydrated in alcohol at -70 °C. It is then coated with a thin film of heavy metal such as platinum or gold.
Q22
According to the comparison of SEM and TEM, the magnifying power of TEM is up to
- A. 1,500X
- B. 100,000X
- C. 5,000,000XCorrect
- D. 2,400X
Explanation. Table 2.2 gives the magnifying power of SEM as up to 100,000X and that of TEM as up to 5,000,000X. TEM can resolve objects as close as 1 nm, while SEM resolution is up to 20 nm.
Q23
The foldscope, an origami based paper microscope, was developed by
- A. Manu PrakashCorrect
- B. Max Knoll
- C. Frits Zernike
- D. De Broglie
Explanation. The foldscope is an optical microscope assembled from simple components including a sheet of paper and a lens. It was developed by an Indian, Manu Prakash, and magnifies from 140X up to 2400X.
Q24
The energy dispersive spectrometer (EDS) detector fitted to SEMs normally consists of
- A. Tungsten or platinum
- B. Semiconducting silicon or germaniumCorrect
- C. Quartz or glass
- D. Copper or aluminium
Explanation. SEMs are equipped with an energy dispersive spectrometer detection system that detects and displays most of the X-ray spectrum. The detector normally consists of semiconducting silicon or germanium.